VPD Calculator

Calculate Vapour Pressure Deficit from temperature and humidity

°C
%
-
kPa

VPD Reference Zones

Range (kPa)StageNotes
< 0.4Too lowHigh disease risk, slow transpiration
0.4 - 0.8Propagation / clonesReduced stress for cuttings and seedlings
0.8 - 1.2VegetativeIdeal for leafy growth
1.2 - 1.6Flowering / fruitingHigher transpiration drives nutrient uptake
> 1.6Too highHeat stress, stomatal closure

Method: SVP calculated using the Magnus formula. VPD = SVPleaf - (RH/100 × SVPair). When no leaf temperature is entered, leaf temperature defaults to air temperature minus 2°C.

Copy and paste into your website or CMS:

<iframe src="http://hortibase.com/tools/vpd-calculator?embed=1" width="100%" height="620" frameborder="0" style="border:1px solid #dee2e6;border-radius:8px;" title="Hortibase Tool"></iframe>

The tool will display with Hortibase branding. No account required.

Powered by Hortibase — The authoritative product database for indoor growing