Air Exchange & Fan Calculator

Calculate the extraction fan size needed for your grow room

m
m
m
15 ACH (CO₂ enriched) 60 ACH (standard) 120 ACH (hot/humid)
Room volume
-
Extraction fan
-
m³/h
- CFM
Intake fan (negative pressure)
-
m³/h
- CFM

Recommended ACH by Setup

ScenarioSuggested ACHAir change interval
CO₂-enriched room (sealed)15 - 302 - 4 min
Standard grow room (temperate)40 - 601 - 1.5 min
High-intensity / high-wattage lighting60 - 9040 - 60 sec
Hot climate or poor insulation90 - 12030 - 40 sec

Formulas: Volume (m³) = L × W × H  |  Extraction (m³/h) = Volume × ACH  |  CFM = m³/h × 0.5886

Tip: Size the intake fan 15 - 20% smaller than the extraction fan to maintain slight negative pressure, which prevents odour escaping and improves air distribution. Add 20 - 25% to fan ratings to account for duct resistance, bends, and carbon filters.