VPD Calculator

Calculate Vapour Pressure Deficit from temperature and humidity

°C
Leave blank to match most controllers (air VPD). Enter a lower value for leaf VPD.
%
-
kPa

VPD Reference Zones

Range (kPa)StageNotes
< 0.4Too lowHigh disease risk, slow transpiration
0.4 - 0.8Propagation / clonesReduced stress for cuttings and seedlings
0.8 - 1.2VegetativeIdeal for leafy growth
1.2 - 1.6Flowering / fruitingHigher transpiration drives nutrient uptake
> 1.6Too highHeat stress, stomatal closure

Method: SVP calculated using the Magnus formula. VPD = SVPleaf - (RH/100 × SVPair). When no leaf temperature is entered, leaf temperature equals air temperature (air VPD), matching most grow-room controllers. Enter a lower leaf temperature for leaf VPD, which is often 1-2°C below air under grow lights.